Bosch Rexroth AG | Pneumatics
Preparation of compressed air → Maintenance units and components
3/2-shut-off valve, mechanically operated, Series NL4-BAV
▶ G 3/8 - G 3/4 ▶ ATEX certified
Part numbers marked in bold are available from the central warehouse in Germany, see the shopping basket for detailed information
Pneumatics catalog, online PDF, as of 200-02-8, © Bosch Rexroth AG, subject to change
0006897
ATEX II 2G2D X
Version Ball valve
with padlock
lockable
Control element rotary switch
Sealing principle metal/metal sealing
Working pressure min./max. 0 bar / 6 bar
Ambient temperature min./max. -0°C / +60°C
Medium temperature min./max. -0°C / +60°C
Medium Compressed air
Materials:
Housing Die cast zinc
Seals Acrylonitrile Butadiene Rubber
Control element Polyoxymethylene
Front cover Acrylonitrile butadiene styrene
Technical Remarks
■ The pressure dew point must be at least 5 °C under ambient and medium temperature and may not exceed 3 °C.
Port Exhaust Qn Weight Part No.
1▶2 2▶3
[l/min] [kg]
G 3/8
G /2 000 0 0.82
0821300912
G /2
0821300911
G 3/4
0821300913
nominal flow Qn with secondary pressure 6 bar at Δp = bar